提供一個VB.NET與OMRON以太網(wǎng)通訊的代碼,是我項目里面復(fù)制出來的:
成都創(chuàng)新互聯(lián)公司是一家集網(wǎng)站建設(shè),城口企業(yè)網(wǎng)站建設(shè),城口品牌網(wǎng)站建設(shè),網(wǎng)站定制,城口網(wǎng)站建設(shè)報價,網(wǎng)絡(luò)營銷,網(wǎng)絡(luò)優(yōu)化,城口網(wǎng)站推廣為一體的創(chuàng)新建站企業(yè),幫助傳統(tǒng)企業(yè)提升企業(yè)形象加強(qiáng)企業(yè)競爭力??沙浞譂M足這一群體相比中小企業(yè)更為豐富、高端、多元的互聯(lián)網(wǎng)需求。同時我們時刻保持專業(yè)、時尚、前沿,時刻以成就客戶成長自我,堅持不斷學(xué)習(xí)、思考、沉淀、凈化自己,讓我們?yōu)楦嗟钠髽I(yè)打造出實用型網(wǎng)站。
Dim?Handle1?As?Int32?'PLC的連接句柄
Dim?EntLink?As?Boolean?'連接標(biāo)志
Dim?PLC?As?New?FinsTcp.PlcClient?'引用OMRON的通訊組件
Private?Sub?butLink_Click(ByVal?sender?As?System.Object,?ByVal?e?As?System.EventArgs)?Handles?butLink.Click
Dim?re?As?Short
Dim?restr?As?String?=?""
re?=?PLC.EntLink(Trim(txtLocalIP.Text),?Val(txtLocalPort.Text),?Trim(txtRemoteIP.Text),?Val(txtRemotePort.Text),?"DEMO",?Handle1)
txtReLink.Text?=?re.ToString
If?re?=?0?Then
EntLink?=?True
MsgBox("PLC聯(lián)接成功!?")
Else
EntLink?=?False
MsgBox("PLC聯(lián)接失敗:?"??restr)
End?If
End?Sub
Private?Sub?butClose_Click(ByVal?sender?As?System.Object,?ByVal?e?As?System.EventArgs)?Handles?butClose.Click
Dim?re?As?Short
EntLink?=?False
re?=?PLC.DeLink(Handle1)
txtReClose.Text?=?re.ToString
End?Sub
Private?Sub?butRead_Click(ByVal?sender?As?System.Object,?ByVal?e?As?System.EventArgs)?Handles?butRead.Click
Dim?re?As?Short
Dim?i?As?Short
Dim?RD()?As?Object
ReDim?RD(Val(txtReadCnt.Text?-?1))
If?Not?EntLink?Then
MsgBox("還未與PLC建立聯(lián)接!")
Exit?Sub
End?If
Dim?mry?As?FinsTcp.PlcClient.PlcMemory?=?cmbReadMry.SelectedIndex?+?1
Dim?typ?As?FinsTcp.PlcClient.DataType?=?cmbReadType.SelectedIndex?+?1
re?=?PLC.CmdRead(Handle1,?mry,?typ,?CUShort(Val(txtReadAdd.Text)),?CUShort(Val(txtReadCnt.Text)),?RD)
txtReRead.Text?=?re.ToString
lstRead.Items.Clear()
For?i?=?0?To?UBound(RD)?Step?1
If?Not?IsNothing(RD(i))?Then?lstRead.Items.Add(RD(i))
Next?i
If?re??0?Then
Timer1.Enabled?=?False
butScan.Text?=?"Cycle?R/W"
End?If
End?Sub
Private?Sub?butWrite_Click(ByVal?sender?As?System.Object,?ByVal?e?As?System.EventArgs)?Handles?butWrite.Click
Dim?re?As?Short
Dim?i?As?Short
Dim?temp()?As?String
Dim?WD()?As?Object
If?Not?EntLink?Then
MsgBox("還未與PLC建立聯(lián)接!")
Exit?Sub
End?If
ReDim?WD(Val(txtWriteCnt.Text)?-?1)
temp?=?Split(txtWrite.Text,?vbCrLf)
For?i?=?0?To?UBound(WD)?Step?1
If?i??UBound(temp)?Then
WD(i)?=?0
Else
WD(i)?=?Trim(temp(i))
End?If
Next?i
Dim?mry?As?FinsTcp.PlcClient.PlcMemory?=?cmbWriteMry.SelectedIndex?+?1
Dim?typ?As?FinsTcp.PlcClient.DataType?=?cmbWriteType.SelectedIndex?+?1
re?=?PLC.CmdWrite(Handle1,?mry,?typ,?CUShort(Val(txtWriteAdd.Text)),?CUShort(Val(txtWriteCnt.Text)),?WD)
txtReWrite.Text?=?re.ToString
If?re??0?Then
Timer1.Enabled?=?False
butScan.Text?=?"Cycle?R/W"
End?If
End?Sub
plc 編程口是usb的 協(xié)議不公開 直接改變不能 但是你可以在plc里寫個通訊程序 比如自由口 串口一 接收到字符 1 把100.0 置1
然后在vb里 調(diào)用 COM控件 發(fā)送字符1 那么plc的 100.0口就可以改變了
西門子:WinTcpS7,三菱:EntQsPlc,歐姆龍:FinsTCP,百度都能搜到資源的;
PLC的協(xié)議廠家一般都不會公開,不過廠家都有提供高級語言開發(fā)的解決方案,百度一下能找到相關(guān)資料,三菱的ENTFXPLC,ENTQSPLC,西門子的WINTCPS7,歐姆龍的FINSTCP都有VB.NET和C#的范例的;
分享標(biāo)題:vb.net與歐姆龍通訊 labview與歐姆龍tcp通訊
標(biāo)題來源:http://jinyejixie.com/article36/dddhcsg.html
成都網(wǎng)站建設(shè)公司_創(chuàng)新互聯(lián),為您提供做網(wǎng)站、動態(tài)網(wǎng)站、全網(wǎng)營銷推廣、標(biāo)簽優(yōu)化、網(wǎng)頁設(shè)計公司、外貿(mào)網(wǎng)站建設(shè)
聲明:本網(wǎng)站發(fā)布的內(nèi)容(圖片、視頻和文字)以用戶投稿、用戶轉(zhuǎn)載內(nèi)容為主,如果涉及侵權(quán)請盡快告知,我們將會在第一時間刪除。文章觀點不代表本網(wǎng)站立場,如需處理請聯(lián)系客服。電話:028-86922220;郵箱:631063699@qq.com。內(nèi)容未經(jīng)允許不得轉(zhuǎn)載,或轉(zhuǎn)載時需注明來源: 創(chuàng)新互聯(lián)